*Most of the records of the intensity in the
list are old. You had better check the latest intensity by using Point
Log.
Select a SiO maser source from the list and push Get button.
Scan table
Push Sample List button on Scan Table Window to open the
sample list. Scan tables for five points method are available from
the list. You can choose a suitable table for the intensity of your
pointing source.
Name
Integration time (sec)
point5
5
point10
10
point20
20
Select a table from the sample list and push Get button.
Device table
Push "Sample List" button on Device Table Window to open the sample
list. Device tables for pointing with S40 and H40 are available from
the list.
Name
RX
AOS
s40sio
S40
High
h40sio
H40
High
pointw1
S40
Wide
pointw2
H40
Wide
Select a table from the sample list and push Get button.
Select a strong source from the list and push Get button.
Scan table
Push Sample List button on Scan Table Window to open
the sample file list. Scan tables for pointing with continuum source
(cross scan) are available from the list. Scan table for NOBA is
also available from the list.
Name
Scan length (')
RX
point2
2
H40, S40, S80, S100, BEARS
point4
4
H20
nobapin
1
NOBA
Select a scan table from the list and push Get button.
Device table
Push Sample List button on Device Table Window to open the
sample file list. Device tables for pointing using a contiuum source
are available from the list.
Name
RX
Frequency (GHz)
h22
H20
23
h40
H40
43
s40
S40
43
s80
S80
86
s100
S100
110
nobax
NOBA
150
Select a device table from the list and push Get button.
* If there is a pointing source which is strong at the observing frequency,
you can use the device table of the main target for pointing also.