The efficiencies of the 45-m radiotelescope 2007-2008

Effective for period between Dec. 2007 - June 2008 (Measured between Nov. and Dec. 2007)

-------------------------------------------------------------------------------
Receiver  Frequency   HPBW     Aperture    Main beam  Calib.     EL.   comment
            (GHz)   (arcsec)   effic(%)    effic(%)   source
-------------------------------------------------------------------------------
S40          43     38.5+-0.1   57+-3      73+-4     Mars        45-51
                                                     3C454.3     63-68

             49     33.3  0.2   57  3      72  4     Mars        59-68
                                                     3C454.3     55-59

S80          86     18.4  0.1   36  2      42  2     Mars        70-71
                                                     3C454.3     38-41

            110     15.3  0.2   27  2      35  2     Mars        52-59
                                                     3C454.3     28-29

            115     14.8  0.3   20  1      27  2     Mars        72-73
                                                     3C454.3     54-55

S100         86     18.2  0.1   38  2      44  2     Mars        54-58
                                                     3C454.3     29-33

            110     14.9  0.1   31  2      40  2     Mars        70-71
                                                     3C454.3     38-40

            115     14.9  0.1   23  1      32  2     Mars        72-73
                                                     3C454.3     54-56
----------------------------------------------------------------------------

The error of the efficiencies is mainly due to uncertainty of brightness temperature of the planet. The error of the efficiencies and beam sizes corresponds to one sigma.

  1. Brightness Temperatures (Tb) of Sources
  2. Diameter of the Planet
  3. References

2008-03-13 nro45mrt @ NRO